Ottawa School Indoor Air Quality Study: Volative Organic Compound (VOC) Dataset (English, CSV)
Ottawa School Indoor Air Quality Study: Volative Organic Compound (VOC) Dataset: English CSV file (146 KB) you can open as a table, filter, chart and export up to 10,000 rows. From Health Canada, updated Jun 2023.
- Format
- CSV
- Access
- Table on demand (prepared when opened)
- Size
- 149,153 bytes
- Publisher-reported update
- 2023-06-14
In 2013, Health Canada conducted an indoor air quality study in 4 schools located near major roads in Ottawa, ON. At each school, a range of air pollutants were monitored both indoors and outdoors for 32 consecutive school days (6.5 hour duration) under both baseline conditions and intervention conditions. The intervention assessed how changing the timing of high ventilation periods impacted indoor air quality in schools. Among the different pollutants measured, volatile organic compounds (VOCs) were collected using Summa™ canisters. The sample canisters were analyzed for 153 polar and non-polar VOCs. This dataset presents the descriptive VOC statistics obtained as part of this study, stratified by intervention status, and is intended to provide relevant Canadian data on indoor exposure to VOCs found in schools.
Data overview
- Formats
- CSV
- File languages
- English
- Available actions
- Explore table (prepared automatically) · Access original file
Sample rows
The first 10 rows, as CanQuery read them from the start of the publisher's file on 2026-11-03.
| index | VOC Species [all concentrations in ug/m3] | CAS # | MDL | Exposure Category | Intervention Period | Count | min | max | % Samples Above MDL | % Schools with all samples > MDL | % Schools with at least one sample > MDL | mean | geomean | 5th Percentile | 25th Percentile | 50th Percentile (Median) | 75th Percentile | 90th Percentile | 95th Percentile |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 1,1,1-Trichloroethane | 71-55-6 | 0.056 | Front Door | Baseline | 54 | <MDL | 0.08 | 68.5 | 0 | 25 | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL |
| 1 | 1,1,1-Trichloroethane | 71-55-6 | 0.056 | Front Door | Intervention | 57 | <MDL | 0.162 | 61.4 | 0 | 25 | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL |
| 1 | 1,1,1-Trichloroethane | 71-55-6 | 0.056 | HVAC | Baseline | 65 | <MDL | <MDL | 55.4 | 0 | 25 | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL |
| 1 | 1,1,1-Trichloroethane | 71-55-6 | 0.056 | HVAC | Intervention | 56 | <MDL | 0.148 | 57.1 | 0 | 25 | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL |
| 1 | 1,1,1-Trichloroethane | 71-55-6 | 0.056 | Indoor | Baseline | 61 | <MDL | 0.056 | 65.6 | 0 | 25 | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL |
| 1 | 1,1,1-Trichloroethane | 71-55-6 | 0.056 | Indoor | Intervention | 62 | <MDL | 0.136 | 59.7 | 0 | 25 | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | 0.072 |
| 1 | 1,1,1-Trichloroethane | 71-55-6 | 0.056 | IO Ratio | Baseline | 61 | 0.875 | 2 | - | - | - | 1.307 | 1.286 | 1 | 1.154 | 1.25 | 1.4 | 1.636 | 1.833 |
| 1 | 1,1,1-Trichloroethane | 71-55-6 | 0.056 | IO Ratio | Intervention | 59 | 0.878 | 3.4 | - | - | - | 1.263 | 1.221 | 1 | 1.077 | 1.167 | 1.333 | 1.615 | 2 |
| 2 | 1,1,2,2-Tetrachloroethane | 79-34-5 | 0.082 | Front Door | Baseline | 54 | <MDL | <MDL | 1.9 | 0 | 25 | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL |
| 2 | 1,1,2,2-Tetrachloroethane | 79-34-5 | 0.082 | Front Door | Intervention | 57 | <MDL | <MDL | 0 | 0 | 0 | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL | <MDL |